Specialty - Anti Fog
CLEAR AB Anti-Fog
Clear AB Anti Fog film helps prevent windows and mirrors from fogging up in situations where ambient temperatures may vary significantly, such as in bathrooms, swimming pools, saunas, cold-rooms, etc.
Tensile strength at break
N/A
Thickness
100 μm
Characteristics
Warranty
2 years
Fire Resistance Rating
M1
Storage in recommended conditions
3 years
REACH / RoHS
Compliant
Widths Available
152 cm
Installation Type
Interior
Color From the Outside
Transparent
Length
30.5 m
Product Carbon Footprint (LCA)
1.23 kgCO2e/m²
Construction
Protection PET release liner, disposable after installation
Scratch-resistant hard coating providing surface protection, durability, and ease of cleaning
High optical quality polyester
Reinforced PS adhesive to accompany the elasticity of the film in case of impact, polymerizes with glass within 30 days
Protection PET release liner, disposable after installation
Composition
PET
Thickness
100 μm
Mechanical Properties
Tensile strength at break
N/A
Elongation at break
N/A
Optical and solar properties
| Sinlge 3mm | Double Low-E | |||||
|---|---|---|---|---|---|---|
| Pane type | No film | With Film | No film | With Film | ||
| UV Rejection (%) | Sinlge 3mm | 25 | 99 | Double Low-E | 40 | 99 |
| Visible Light Transmission (%) | Sinlge 3mm | 91 | 87 | Double Low-E | 82 | 79 |
| Visible Light Reflection - External (%) | Sinlge 3mm | 8 | 11 | Double Low-E | 11 | 16 |
| Visible Light Reflection - Internal (%) | Sinlge 3mm | 8 | 11 | Double Low-E | 12 | 16 |
| Solar Energy Reflection (%) | Sinlge 3mm | 5 | 10 | Double Low-E | 12 | 24 |
| Solar Energy Absorption (%) | Sinlge 3mm | 8 | 14 | Double Low-E | 28 | 26 |
| Solar Energy Transmission (%) | Sinlge 3mm | 87 | 76 | Double Low-E | 60 | 50 |
| Total Solar Energy Rejected (%) | Sinlge 3mm | 12 | 18 | Double Low-E | 35 | 35 |
| Glare Reduction (%) | Sinlge 3mm | - | 14 | Double Low-E | - | 4 |
| Shading Coefficient | Sinlge 3mm | - | 0.90 | Double Low-E | - | 1.0 |
| g-value | Sinlge 3mm | 0.88 | 0.82 | Double Low-E | 0.65 | 0.65 |
Application advice01
Vertical situation and for a standard glazed surface
| Clear Single Pane | |
| Tinted Single Pane | |
| Reflective Tinted Single Pane | |
| Clear Double Pane | |
| Tinted Double Pane | |
| Reflective Tinted Double Pane | |
| Gas-Filled Double Pane - Low E | |
| Stadip Ext. Clear Double Pane | |
| Stadip Int. Clear Double Pane |
01
Advice based on glazed surface area up to 2.5 m², please contact us for any confirmation or thermal shock analysis.The data in this information sheet is not contractual, SOLAR SCREEN reserves the right to modify the composition of its products at any time. Please refer to our warranties and general sales conditions.
Installation and Maintenance Advise
Use Slide On (600-FO2) or Film On (600-F0355) diluted at 2 cL/L of water for installation and cleaning. Do not clean for one month after installation or apply stickers/adhesives on the film.