Master 870 XC
Master 870XC is a next-generation polyurethane-based solar control film engineered for non-mineral substrates such as polycarbonate and PMMA, delivering over 95% infrared rejection with a neutral, non-reflective appearance that preserves natural light and blends seamlessly into any urban, industrial, or airport roofing environment. At 4x the thickness of a standard solar film, its flexible TPU construction not only enables effortless installation on curved and complex surfaces, but also structurally reinforces the substrate it bonds to, backed by a 5-year warranty for long-lasting.
Values based on a study carried out on an air-conditioned building located in Luxembourg, with a film applied on a low-E double glazing, facing East. The heating months considered are from October to March, and the cooling months from April to September. We consider an electric heating system of the heat pump type, with a production efficiency of 3.5 and an electric cooling system with an efficiency of 3. For more information, visit our online tool.
| Single 3mm | Double Low-E | |||||
|---|---|---|---|---|---|---|
| Pane type | No film | With Film | No film | With Film | ||
| UV Rejection (%) | Single 3mm | 25 | 99 | Double Low-E | 40 | 99 |
| Visible Light Transmission (%) | Single 3mm | 91 | 35 | Double Low-E | 82 | 32 |
| Visible Light Reflection - External (%) | Single 3mm | 8 | 5 | Double Low-E | 11 | 6 |
| Visible Light Reflection - Internal (%) | Single 3mm | 8 | 5 | Double Low-E | 12 | 6 |
| Solar Energy Reflection (%) | Single 3mm | 5 | 5 | Double Low-E | 28 | 5 |
| Solar Energy Absorption (%) | Single 3mm | 8 | 75 | Double Low-E | 12 | 79 |
| Solar Energy Transmission (%) | Single 3mm | 87 | 20 | Double Low-E | 60 | 16 |
| Total Solar Energy Rejected (%) | Single 3mm | 12 | 63 | Double Low-E | 35 | 79 |
| Infrared Rejection (780 - 2500 nm) (%) | Single 3mm | 16 | 96 | Double Low-E | 16 | 97 |
| Glare Reduction (%) | Single 3mm | - | 59 | Double Low-E | - | 61 |
| Shading Coefficient | Single 3mm | - | 0.43 | Double Low-E | - | 0.24 |
| g-value | Single 3mm | 0.88 | 0.37 | Double Low-E | 0.65 | 0.21 |
| U-value (W/m².°C) | Single 3mm | 5.8 | 5.8 | Double Low-E | 1.1 | 1.1 |
| Clear Single Pane | |
| Tinted Single Pane | |
| Reflective Tinted Single Pane | |
| Clear Double Pane | |
| Tinted Double Pane | |
| Reflective Tinted Double Pane | |
| Gas-Filled Double Pane - Low E | |
| Stadip Ext. Clear Double Pane | |
| Stadip Int. Clear Double Pane |
Advice based on glazed surface area up to 2.5 m², please contact us for any confirmation or thermal shock analysis.The data in this information sheet is not contractual, SOLAR SCREEN reserves the right to modify the composition of its products at any time. Please refer to our warranties and general sales conditions.